BOF-125S Series
■ Feature
● Universal AC Input: 85~265VAC/100~370VDC, Active PFC,PF>0.96@230Vac, >0.98@115Vac
● Small Size,3*
● Very wide working temperature (-25℃~
● Protection:Overload/Short/Over voltage
● LED indicator,output voltage adjusted ,Built-in remote sense
● All capacitor used high working temperature
● 2 year warranty
■SPEC
Model
BOF-125S5
BOF-125S12
BOF-125S15
BOF-125S24
BOF-125S27
BOF-125S48
BOF-125S140
Output
Output Voltage
5V
12V
15V
24V
27V
48V
140V
Rated Current(convention)
0~20A
0~8.5A
0~6.7A
0~4.2A
0~3.8A
0~2.1A
0~1.0A
Rated Current(18CFM)
0~25A
0~10.5A
0~8.4A
0~5.2A
0~4.6A
0~2.6A
/
Ripple & Noise 0~70℃
80mV
100mV
100mV
150mV
150mV
250mV
250mV
DC adjustment range
-5% ~ +10% of rated output voltage
Output Voltage Tolerence
±2.0%
±2.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
Setup time
≤1S (230Vac input, Full load)
Hold up time
≥20mS(230Vac input, Full load)
Input
Input Voltage range
90Vac~264Vac
Rated Input Voltage
100Vac~240Vac
PF
>0.96 230Vac Full Load; >0.98 115Vac Full Load
Efficient (Type)
85%
87%
87%
88%
88%
88%
90%
Start-up Inrush Current
<20A@115Vac <40A@230Vac Cold start
- Previous Product:BOU-45S Series